Intel Storage System SSR212PP User Guide 159
28
PRELIMINARY
Verifying the Failover
Configuration
Before you store data on virtual disks, use the procedure in this section to verify that:
The server can send data to and receive data from the storage system.
You can download an I/O simulator (Iometer) for writing data to the storage system
from the following website: http://www/iometer.org/.
PowerPath shows the paths from the server to the virtual disk that you expect for your
configuration.
Verifying the Failover Configuration for a Windows 2003
Server Host
STEP 1. If you connected a new server to an existing storage system, stop all applications
accessing the storage system and disable user logins to the server.
STEP 2. Start PowerPath for iSCSI:
i. Select
Start
Settings
Control Panel.
ii. On the Control Panel, do one of the following:
¥Select
Administrative Tools
Computer Management, or
¥Click the
My Computer icon on your Desktop and select Manage from the menu.
The PowerPath iSCSI application resides under the
Storage component of the
Computer Management utility.
STEP 3. On the Computer Management panel, select PowerPath iSCSI.
STEP 4. In the left pane, expand Disks.
STEP 5. Click on each virtual disk to display a list of :paths to the disk, and verify that all paths are
listed. (Missing or failed paths do not, appear in the list of paths.)
If a path is missing, refer to the "Troubleshoot" section on the SSR212PP support
website or the SSR212PP2f-Series Documentation CD.
STEP 6. Start writing data to a virtual disk.
STEP 7. For each NIC or iSCSI HBA connected to the storage system:
a. Disconnect the cable from one NIC or iSCSI HBA connected to the storage system.