Intel SSR212PP Network Card User Manual


 
138 Intel Storage System SSR212PP User Guide
Revision 1.0
PRELIMINARY
To set up mutual CHAP you must first configure advanced initiator CHAP.
On each server that will use the storage system, configure initiator CHAP by entering
the user data for each initiator that will connect to the target. The initiator sends this
data to the target and the target uses this data to authenticate the initiator.
On each server, ensure that the target is logged in to the initiators.ensure that the
session is active, and that HBAs are logged in to the target.
After you decide on the security level you want to configure in your SSR212PP2f-Series
environment, follow the instructions in either the section on setting up basic or advanced
CHAP the NICs or iSCSI HBAs.
Before You Start
Make sure that you complete the CHAP worksheets in Procedure 3, "Planning Your iSCSI
Storage System Configuration," on page 15, and that you have the worksheets available.
If your system utilizes QLogic iSCSI HBAs, refer to the QLogic documentation supplied
with the HBA for more information. Note that QLogic uses the following terminology:
Removing iSCSI Targets
STEP 1. On a Windows server without iSNS: log off and remove targets:
When you remove an iSCSI target, the specified target and all other targets on the
storage system will be removed. If you want to remove a specific target port and
not all targets on the storage system, you must use the Microsoft Software Initiator.
a. On the server that includes your iSCSI initiators, open the Navisphere Server Utility.
See Procedure 30, "Running the Navisphere Server Utility," on page 165.
b. Log off and remove any targets with the storage system you are setting up for CHAP:
i. Select
Congure iSCSI Connections on this server and then Congure iSCSI
Connections.
ii. In the
iSCSI Targets and Connections window, under View iSCSI Connections,
select
View currently available targets.
iii. Click
Next. The utility scans for target ports and displays the IP address for each
target it discovers.
iv. In the
iSCSI Targets window, select the IP address of the Connected target and
click
Logoff. The target status changes to Inactive.
EMC terminology QLogic terminology
CHAP Username
Initiator Name
CHAP Secret
Initiator Secret
Initiator (Basic) CHAP
CHAP