Intel SSR212PP Network Card User Manual


 
160 Intel Storage System SSR212PP User Guide
Revision 1.0
PRELIMINARY
b. Scan for hardware changes:
i. On the desktop, right-click
My Computer and click Manage.
ii. In the tree under
System Tools, click Device Manager.
iii. Click
Disk Drives and Scan for hardware changes.
c. Verify that at least one path is missing to the disk to which you are writing data:
i. Under
PowerPath iSCSI (under Computer Management), expand Disks.
ii. Click the disk to which you are writing data and verify the its path list has at least
one path missing.
d. Reconnect the cable that you disconnected from theNIC or iSCSI HBA.
e. Scan again for hardware changes:
i. On the desktop, right-click
My Computer and click Manage.
ii. In the tree under
System Tools, click Device Manager.
iii. Click
Disk Drives and then Scan for hardware changes.
f. Verify the paths to the disk to which you are writing data:
i. Under
PowerPath iSCSI (under Computer Management), expand Disks.
ii. Click the disk to which you are writing data and verify that its path list has all
paths listed and that one path is active.
STEP 8. Restart any applications that you stopped and re-enable any user logins to the server that
you disabled.