SSR212PPi Directly Connected to One Server
Figure 5 shows one server, with two iSCSI initiators, directly cabled to an SSR212PPi s
iSCSI data ports.
FIGURE 5. SSR212PPi (Single SP) Directly Connected to One Server
Sample IP Addresses
Port IP address Subnet mask Gateway
Storage Processor A iSCSI port 0 172.31.1.150 255.255.255.0 0.0.0.0
Storage Processor A iSCSI port 1 172.31.2.150 255.255.255.0 0.0.0.0
iSCSI NIC/HBA 1 172.31.1.101 255.255.255.0 0.0.0.0
iSCSI NIC/HBA 2 172.31.2.101 255.255.255.0 0.0.0.0
Management port IP addresses should match the corporate network scheme.
Advantages
You can easily migrate this low-cost storage for a single server to a switched
environment.
The dedicated iSCSI path ensures maximum throughput from the host to the storage
system.
The dedicated path provides inherent security.
Disadvantages
Since only one server can connect to the storage system, this configuration does not
take full advantage of the SSR212PPi s connectivity capabilities.
While this configuration provides port failover and load balancing, it does not allow
SP failover.