Chapter 4 Register Map and Descriptions
©
National Instruments Corporation 4-63 AT-MIO-16X User Manual
Calibration DAC 1 Load Register
Accessing the Calibration DAC 1 Load Register loads the serial data
shifted into the 12-bit ADC pregain offset calibration DACs.
Address: Base address + 1A (hex)
Type: Write-only
Word Size: 8-bit
Bit Map: Not applicable, no bits used
Strobe Effect: Updates the ADC pregain offset calibration DAC