Chapter 5 Programming
©
National Instruments Corporation 5-29 AT-MIO-16X User Manual
Figure 5-8. Programmed Cycle Waveform Programming
END
START
Clear the analog output
circuitry including the DAC
FIFO
Program the update
interval counter
Set the A4RCV bit in
Command Register 2
Set the waveform
generation mode
Service update requests
Clear the A4RCV bit in
Command Register 2
Yes
No
Enable updating
Program the cycle counter
Select the update counter
via RTSI programming
Internal
update ?