National Instruments AT-MIO-16X Switch User Manual


 
Chapter 4 Register Map and Descriptions
AT-MIO-16X User Manual 4-2
©
National Instruments Corporation
Analog Output Register Group
DAC0 Register
DAC1 Register
10
12
Write-only
Write-only
16-bit
16-bit
ADC Event Strobe Register Group
CONFIGMEMCLR Register
CONFIGMEMLD Register
DAQ Clear Register
DAQ Start Register
Single Conversion Register
ADC Calibration Register
1B
1B
19
1D
1D
1F
Read-only
Write-only
Read-only
Read-only
Write-only
Write-only
8-bit
8-bit
8-bit
8-bit
8-bit
8-bit
DAC Event Strobe Register Group
TMRREQ Clear Register
DAC Update Register
DAC Clear Register
1F
18
1E
Read-only
Write-only
Read-only
8-bit
16-bit
8-bit
General Event Strobe Register Group
DMA Channel Clear Register
DMATCA Clear Register
DMATCB Clear Register
External Strobe Register
Calibration DAC 0 Load Register
Calibration DAC 1 Load Register
0B
19
09
1E
0A
1A
Read-only
Write-only
Read-only
Write-only
Write-only
Write-only
8-bit
8-bit
8-bit
8-bit
8-bit
8-bit
Am9513A Counter/Timer Register Group
Am9513A Data Register
Am9513A Command Register
Am9513A Status Register
14
16
16
Read-and-write
Write-only
Read-only
16-bit
16-bit
16-bit
Digital I/O Register Group
Digital Input Register
Digital Output Register
1C
1C
Read-only
Write-only
16-bit
16-bit
RTSI Switch Register Group
RTSI Switch Shift Register
RTSI Switch Strobe Register
0C
0E
Write-only
Write-only
8-bit
8-bit
Table 4-1. AT-MIO-16X Register Map (Continued)
Register Name Offset
Address (Hex)
Type Size