Toshiba VF-FS1 Power Supply User Manual


 
E6581381
F-9
6
Assigning one function to an output terminal
Terminal
symbol
Title Function Adjustment range Default setting
RY - RC
H
Output terminal selection 1A
4 (Low-speed
detection signal)
FL
(A, B, C
H
Output terminal selection 3
0-255
(
See page K-17)
10(Failure FL)
+ When assigning one function to RY-RC terminals, set parameter H only.
Do not change but leave parameters
H and H as they were set by default.
(Default setting:
H=255, H=0)
6.3.4 Assigning two functions to an output terminal
H
: Output terminal selection 1A (RY-RC)
H
: Output terminal selection 1B (RY-RC)
H
: Output terminal logic selection (RY-RC)
Function
2 different functions can be assigned to the terminal board output terminal RY-RC.
Signals of 2 functions of the logical product (AND) or logical sum (OR) selected form 58 functions can
be output to 1 output terminal.