Toshiba VF-FS1 Power Supply User Manual


 
E6581381
H-7
8
(Continued)
Item displayed
Key
operated
LED
display
Communic
ation No.
Description
Torqu e SQ FE18
The torque at the occurrence of a trip (%) is
displayed.
Torque current
Y
FE20
The torque current (%/A) at the occurrence of a
trip is displayed.
Inverter load factor
N
FE27
The inverter load factor (%) at the occurrence of a
trip is displayed.
Input power
M
FE29
The inverter input power (kW) at the occurrence of
a trip is displayed.
Output power
J
FE30
The inverter output power (kW) at the occurrence
of a trip is displayed.
Operation
frequency
Z
FE00
The inverter output frequency (Hz/free unit) at the
occurrence of a trip is displayed.
Input terminal __KK FE06
The ON/OFF statuses of the control input
terminals (F, R, RES and VIA) are displayed in
bits.
ON:
OFF: _
Output terminal _K FE07
The ON/OFF status of each of the control signal
output terminals (RY and FL) at the occurrence of
a trip is displayed in bits.
ON:
OFF: _
CPU1 version
X
FE08 The version of the CPU1 is displayed.
CPU2 version XY FE73 The version of the CPU2 is displayed.
Memory version
XG
FE09 The version of the memory mounted is displayed.
PID feedback F FE22
The PID feedback value at the occurrence of a trip
is displayed. (Hz/free unit)
Frequency
command value
(PID-computed)
D FE15
The PID-computed frequency command value at
the occurrence of a trip is displayed. (Hz/free unit)
Integral input
power
M FE76
The integrated amount of power (kWh) supplied to
the inverter is displayed.
(0.01=1kWh, 1.00=100kWh)
(Continued overleaf)
_K
RY-RC
FL
__KK
VIA
RES
R
F
Note 4