E6581381
H-7
8
(Continued)
Item displayed
Key
operated
LED
display
Communic
ation No.
Description
Torqu e SQ FE18
The torque at the occurrence of a trip (%) is
displayed.
Torque current
Y
FE20
The torque current (%/A) at the occurrence of a
trip is displayed.
Inverter load factor
N
FE27
The inverter load factor (%) at the occurrence of a
trip is displayed.
Input power
M
FE29
The inverter input power (kW) at the occurrence of
a trip is displayed.
Output power
J
FE30
The inverter output power (kW) at the occurrence
of a trip is displayed.
Operation
frequency
Z
FE00
The inverter output frequency (Hz/free unit) at the
occurrence of a trip is displayed.
Input terminal __KK FE06
The ON/OFF statuses of the control input
terminals (F, R, RES and VIA) are displayed in
bits.
ON:
OFF: _
Output terminal _K FE07
The ON/OFF status of each of the control signal
output terminals (RY and FL) at the occurrence of
a trip is displayed in bits.
ON:
OFF: _
CPU1 version
X
FE08 The version of the CPU1 is displayed.
CPU2 version XY FE73 The version of the CPU2 is displayed.
Memory version
XG
FE09 The version of the memory mounted is displayed.
PID feedback F FE22
The PID feedback value at the occurrence of a trip
is displayed. (Hz/free unit)
Frequency
command value
(PID-computed)
D FE15
The PID-computed frequency command value at
the occurrence of a trip is displayed. (Hz/free unit)
Integral input
power
M FE76
The integrated amount of power (kWh) supplied to
the inverter is displayed.
(0.01=1kWh, 1.00=100kWh)
(Continued overleaf)
_K
RY-RC
FL
__KK
VIA
RES
R
F
Note 4