Toshiba VF-FS1 Power Supply User Manual


 
E6581381
K-3
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
RV
0015 V/F control mode
selection
- - 0: V/F constant
1: Variable torque
2: Automatic torque boost control
3: Vector control
4: Energy-saving
5: - (Do not select)
6: PM motor control
25.10
XD
0016 Torque boost 1 % 0.1/0.1 0.0-30.0 * 2 5.11
VJT
0600 Motor electronic-
thermal protection
level 1
%
(A)
1/1 10-100 100 5.12
6.17.1
Setting Overload protection OL stall
0
{
×
1 {{
2
××
3
Standard
motor
×
{
4
{
×
5 {{
6
××
QNO
0017 Electronic-thermal
protection
characteristic
selection *3
--
7
VF motor
×
{
05.12
UT
0018 Preset-speed
operation
frequency 1
Hz 0.1/0.01 NN-WN 15.0
UT
0019 Preset-speed
operation
frequency 2
Hz 0.1/0.01 NN-WN 20.0
UT
0020 Preset-speed
operation
frequency 3
Hz 0.1/0.01 NN-WN 25.0
UT
0021 Preset-speed
operation
frequency 4
Hz 0.1/0.01 NN-WN 30.0
UT
0022 Preset-speed
operation
frequency 5
Hz 0.1/0.01 NN-WN 35.0
UT
0023 Preset-speed
operation
frequency 6
Hz 0.1/0.01 NN-WN 40.0
UT
0024 Preset-speed
operation
frequency 7
Hz 0.1/0.01 NN-WN 45.0
5.13
H
- Extended
parameters
- - - - - 4.2.2
ITW
- Automatic edit
function
- - - - - 4.2.3
*1 : 230 (WP/WN type), 400 (WP type), 460 (WN type)
*2 : Default values vary depending on the capacity. See the table of page K-14.
*3 : { : valid, × : invalid