E6581381
K-10
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
H
0609 Small current
detection current
hysteresis
% 1/1 1-20 10
H
0610 Small current
trip/alarm
selection
- - 0: Alarm only
1: Tripping
0
H
0611 Small current
detection current
%
(A)
1/1 0-100 0
H
0612 Small current
detection time
s 1/1 0-255 0
6.17.7
H
0613 Detection of
output short-circuit
during start-up
- - 0: Each time (standard pulse)
1: Only one time after power is turned
on (standard pulse)
2: Each time (short-time pulse)
3: Only one time after power is turned
on (short-time pulse)
0 6.17.8
H
0615 Over-torque
trip/alarm
selection
- - 0: Alarm only
1: Tripping
0
H
0616 Over-torque
detection level
%
1/1 0-200 130
H
0618 Over-torque
detection time
s 0.1/0.1 0.0-10.0 0.5
6.17.9
H
0619 Over-torque
detection level
hysteresis
% 1/1 0-100 10
H
0621 Cumulative
operation time
alarm setting
100
Time
0.1/0.1
(=10 hours)
0.0-999.9 610.0 6.17.10
H
0626 Overvoltage limit
operation level
%
1/1 100-150 140 6.12.4
H
0627 Undervoltage
trip/alarm
selection
- - 0: Alarm only
(detection level below 60%)
1: Tripping
(detection level below 60%)
2: Alarm only
(detection level below 50%,
input reactor necessary)
0 6.17.12
H
0632 Thermal memory
selection
- - 0: Disabled
1: Enabled
0 6.17.1
H
0633 Trip at VIA low
level input mode
% 1/1 0: Disabled, 1-100 0 6.17.13
H
0634 Annual average
ambient
temperature (For
parts replacement
alarms)
- - 1: -10 to +10°C
2: 11-20°C
3: 21-30°C
4: 31-40°C
5: 41-50°C
6: 51-60°C
3 6.17.14
H
0645 PTC thermal
selection
- - 0: Disabled
1: Enabled (trip mode)
2: Enabled (alarm mode)
0 6.17.15
H
0646 PTC detection
resistor value
Ω
1/1 100-9999 3000
H
0650 Forced fire-speed
control selection
- - 0: Disabled
1: Enabled
06.18