6.17.3 Inverter trip retention
H : Inverter trip retention selection
Function
If the inverter trips, this parameter will retain the corresponding trip information.
Trip information that
has thus been stored into memory can be displayed, even after power has been reset.
[Parameter setting]
Title Function Adjustment range Default setting
H
Inverter trip retention selection
0: Canceled with the power off
1: Still retained with the power off
0
+ The causes of up to four trips that occurred in the past can be displayed in status monitor mode.
+ Data displayed in status monitor mode when the inverter is tripped is cleared when power is turned off.
Past trip records can be displayed.
+ Trip records are retained even if power is turned off and turned back on during retry operation.
Flow of operation when H=
Occurrence of a
trip
Reset the
inverter by
panel or
terminal
operation.
Turn power off,
then turn it back
on to reset the
inverter.
Completion of reset
If the cause of the
trip is not
eliminated
If the cause of the
trip is eliminated
Normal operation
The relay trips again.
Display of the cause
Failure signal FL
activated
Trip state is retained
Display of the cause
Failure signal FL not
activated