Toshiba VF-FS1 Power Supply User Manual


 
E6581381
D-4
4
4.2.1 How to set the basic parameters
All of the basic parameters can be set by the same step procedures.
                                         
Switches to the setting monitor mode.
* Parameters were
factory-set by default
before shipment.
* Select the parameter to
be changed from "Table
of parameters".
* If there is something
that you do not
understand during the
operation, press the
MODE key to return to
the

indication.
See section 11.2 for
basic parameters.
Reads the programmed parameter
setting.
Saves the changed value of the
parameter setting.
Selects parameter to be changed.
Changes the parameter setting.
[Steps in key entry for basic parameters]
Example of setting procedure (Changing the maximum frequency from 80Hz to 60Hz).
Key operated LED display Operation

Displays the operation frequency (operation stopped).
(When standard monitor display selection H= [Operation
frequency])
CWH
The first basic parameter “CWH” (Wizard function) is displayed.
HJ
Press either the or key to select “HJ”.

Pressing the ENT key reads the maximum frequency.

Press the key to change the maximum frequency to 60Hz.
HJ
Press the ENT key to save the maximum frequency. HJ and the
frequency are displayed alternately.
After this,
Displays the same
programmed
parameter.
Switches to the
display in the
status monitor
mode.
Displays names
of other
parameters.
ENT
MODE
ENT
ENT
MODE
MODE
ENT
ENT