6.22 Parameters for options
H : Parameter for option 1
H
: Parameter for option 2
H
: Parameter for option 3
H
: Parameter for option 4
H
: Parameter for option 5
These parameters can be used only when specific optional parts are installed. Do not use these parameters
unless such parts are installed.
6.23 Permanent magnetic motors
H : Step-out detection current level
H
: Step-out detection time
H
: High-speed torque adjustment coefficient
Function
If the permanent magnet motor (PM motor) steps out and if the exciting current increases (it increases
in such a case) and remains above the value set with H for the period of time set with H,
the inverter will judge the motor to be stepping out and trip it. At that time, the trip message
"UQWV" is displayed.
Title Function Adjustment range Default setting
H
Step-out detection current level 10 ~ 150 (%) / (A) 100
H
Step-out detection time
0.0: No detection
0.1 ~ 25.0 [s]
0.0
H
High-speed torque adjustment coefficient 0.00 ~ 650.0 0.00
Note 1: When using an PM motor, consult your Toshiba dealer, since the inverter is not compatible with all
types of PM motors.
Note 2: The inverter may fail to detect step-out in some cases, because it uses an electrical method to detect
step-out. To avoid detection failures, you are recommended to install a mechanical step-out detector.
Note 3: There is no need adjust H under normal conditions. (Do not change the setting, unless
otherwise instructed by Toshiba technical staff.)
H : Parameter for option 6
H
: Parameter for option 7
H
: Parameter for option 8
H
: Parameter for option 9
H
: Parameter for option 10