Toshiba VF-FS1 Power Supply User Manual


 
E6581381
E-14
5
Default setting (V[R = )
Setting V[R to will return all parameters to the standard values that were programmed at the factory.
See section 4.2.7.
+ When 3 is programmed, <KPKV will be displayed for a short time after setting and will then be erased
and displayed the original indication .. Trip history data will be cleared at this time.
Trip clear (V[R = )
Setting V[R to initializes the past four sets of recorded error history data.
+ The parameter does not change.
Cumulative operation time clear (V[R = )
Setting V[R to resets the cumulative operation time to the initial value (zero).
Cumulative operation time clear (V[R = )
Setting V[Rto clears the trips when an GV[R format error occurs. But if the GV[R displayed, call us.
Save user setting parameters (V[R = )
Setting V[R to saves the current settings of all parameters.
See section 4.2.8.
Load user setting parameters (V[R = )
Setting V[R to loads parameter settings to (calls up) those saved by setting V[R to .
See section 4.2.8.
+ By setting V[R to or , you can use parameters as your own default parameters.
Cumulative fan operation time record clear (V[R = )
Setting V[R to resets the cumulative operation time to the initial value (zero).
Set this parameter when replacing the cooling fan, and so on.