5
3) Using other speed commands with preset-speed command
Command mode
selection
EOQF
0: Terminal board 1: Operation panel 2: Serial communication
Frequency setting
mode selection
HOQF
1: VIA
2: VIB
5: UP/DOWN
3: Operation
panel
4:Commun
ication
1: VIA
2: VIB
5: UP/DOWN
3: Operation
panel
4:Commun
ication
1: VIA
2: VIB
5: UP/DOWN
3: Operation
panel
4:Commun
ication
Entered Preset-speed command valid Note)
Terminal
command
valid
Operation
panel
command
valid
Terminal
command
valid
Operation
panel
command
valid
Communicatio
n command
valid
Communic
ation
command
valid
Preset-
speed
command
Not
entered
Terminal
command
valid
Operation
panel
command
valid
Communic
ation
command
valid
Note: The preset-speed command is always given priority when other speed commands are input at the
same time.
Below is an example of 7-step speed operation.
ON
OFF
F-CC
R-CC
RES-CC
VIA-CC
ON
OFF
ON
OFF
ON
OFF
UT
UT
UT
UT
UT
UT
UT
Output frequency
[Hz]
Time
[sec]
0
Example of 7-step speed operation
(The inverter doesn't accept Preset-
speed command.)