Toshiba VF-FS1 Power Supply User Manual


 
E6581381
E-8
5
EOQF : Command mode selection
HOQF
: Frequency setting mode selection 1
Function
Remote mode selection, these parameters are used to specify which input device (operation panel,
terminal board, serial communication) takes priority in entering an operation stop command or a frequency
setting command, VIA, VIB, operation panel, serial communication device, external contact up/down).
At Local mode selection, the start/stop operation and frequency setting by operation panel is prior with no
relation of EOQF/HOQFsetting.
<Command mode selection>
Title Function Adjustment range Default setting
EOQF Command mode selection
0: Terminal board
1: Operation panel
2: Serial communication
0
Programmed value
:
Terminal board
operation
ON and OFF of an external signal Runs and stops operation.
:
Operation panel
operation
Press the and keys on the operation panel to start and stop.

Serial communication
operation
Run and stop through serial communication.
* There are two types of function: the function that conforms to commands selected by EOQF, and the function
that conforms only to commands from the terminal board.
See the table of input terminal function selection in Chapter 11.
* When priority is given to commands from a linked computer or terminal board, they have priority over the
setting of EOQF.
STOPRUN