Toshiba VF-FS1 Power Supply User Manual


 
E6581381
F-16
6
6.5.2 Setting frequency command characteristics
H : VIA input point 1 setting
H
: VIA input point 1 frequency
H
: VIA input point 2 setting
H
: VIA input point 2 frequency
H
: VIB input point 1 setting
H
: VIB input point 1 frequency
H
: VIB input point 2 setting
H
: VIB input point 2 frequency
H
: Communication command point 1 setting
H
: Communication command point 1 frequency
H
: Communication command point 2 setting
H
: Communication command point 2 frequency
Function
These parameters adjust the output frequency according to the externally applied analog signal (0-
10Vdc voltage, 4-20mAdc current) and the entered command for setting an external contact
frequency.
+ To fine adjust the frequency command characteristics for VIA/VIB input, use the parameters H to
H. See section 6.5.4.