Toshiba VF-FS1 Power Supply User Manual


 
E6581381
K-9
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
H
0496 Waveform switching
adjustment
coefficient
kHz 0.1/0. 1 0.1-14.0 14.0 5.10
6.15.2
*1 : Default values vary depending on the capacity. See the table of page K-14.
Acceleration/deceleration time parameters
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
H
0500 Acceleration time
2
s 0.1/0.1 0.0-3200 * 1
H
0501 Deceleration time
2
s 0.1/0.1 0.0-3200 * 1
H
0502 Acceleration/decel
eration 1 pattern
-- 0
H
0503 Acceleration/decel
eration 2 pattern
--
0: Linear
1: S-pattern 1
2: S-pattern 2
0
H
0504 Selecting an
acceleration/decel
eration pattern
- - 1: Acceleration/deceleration 1
2: Acceleration/deceleration 2
1
H
0505 Acceleration/decel
eration 1 and 2
switching
frequency
Hz 0.1/0.01 0.0-WN 0.0
H
0506 S-pattern lower-
limit adjustment
amount
% 1/1 0-50 10
6.16
H
0507 S-pattern upper-
limit adjustment
amount
% 1/1 0-50 10
*1 : Default values vary depending on the capacity. See the table of page K-14.
Protection parameters
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
H
0601 Stall prevention
level 1
%
(A)
1/1
10-110
111 (disabled)
110
6.17.2
H
0602
Inverter trip
retention selection
- - 0: Canceled with the power off
1: Still retained with the power off
0 6.17.3
H
0603 Emergency stop
selection
- - 0: Coast stop
1: Slowdown stop
2: Emergency DC braking
0
6.17.4
H
0604 Emergency DC
braking time
s
0.1/0.1 0.0-20.0
1.0
H
0605
Output phase
failure detection
mode selection
-
-
0: Disabled
1: At start-up (only one time after
power is turned on)
2: At start-up (each time)
3: During operation
4: At start-up + during operation
5: Detection of cutoff on output side
0
6.17.5
H
0607 Motor 150%-
overload time limit
s 1/1 10-2400 300 6.17.1
H
0608 Input phase failure
detection mode