Selection of wiring devices
Input current (A)
Molded case circuit
breaker (MCCB)
Earth leakage circuit
breaker (ELCB)
Magnetic contactor
(MC)
Voltage class
Capacity of
applicable
motor
(kW)
200V class:200V
400V class:380V
200V class:240V
400V class:480V
Inverter model
Rated current (A)
Operational current(A)
AC-1
0.4
1.9 1.6
VFFS1-2004PM 3 25
0.75
3.3 2.7
VFFS1-2007PM 5 25
1.5
6.1 5.1
VFFS1-2015PM 10 25
2.2
8.7 7.3
VFFS1-2022PM 15 25
4
15.7 13.0
VFFS1-2037PM 30 25
5.5
20.8 17.3
VFFS1-2055PM 40 32
7.5
27.9 23.3
VFFS1-2075PM 50 40
11
42.1 34.4
VFFS1-2110PM 75 50
15
56.1 45.5
VFFS1-2150PM 100 80
18.5
67.3 55.8
VFFS1-2185PM 100 80
22
80.4 66.4
VFFS1-2220PM 125 100
Three-phase
200V class
30
113.3 89.5
VFFS1-2300PM 175 125
0.4
1.0 0.8
VFFS1-4004PL
3
25
0.75
1.7 1.4
VFFS1-4007PL
3
25
1.5
3.2 2.5
VFFS1-4015PL
5
25
2.2
4.6 3.6
VFFS1-4022PL
10
25
4
8.1 6.4
VFFS1-4037PL
15
25
5.5
10.9 8.6
VFFS1-4055PL
20
25
7.5
14.7 11.7
VFFS1-4075PL
30
32
11
21.1 16.8
VFFS1-4110PL
40
32
15
28.5 22.8
VFFS1-4150PL
50
40
18.5
34.8 27.8
VFFS1-4185PL
60
50
22
41.6 33.1
VFFS1-4220PL
75
80
Three-phase
400V class
Note 4)
30
56.7 44.7
VFFS1-42300PL
100
80
Note 1: Selections for use of the Toshiba 4-pole standard motor with power supply voltage of 200V/400V-50Hz.
Note 2: Choose the MCCB according to the power supply capacity.
For comply with UL and CSA standard, use the fuse certified by UL and CSA.
Note 3: When using on the motor side during commercial-power supply operation, choose the MC with class
AC-3 rated current for the motor rated current.
Note 4: Attach surge killers to the magnetic contactor and exciting coil of the relay.
Note 5: In the case the magnetic contactor (MC) with 2a-type auxiliary contacts is used for the control circuit,
raise the reliability of the contact by using 2a-type contacts in parallel connection.