Toshiba VF-FS1 Power Supply User Manual


 
E6581381
K-2
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
HOUN
0005 Meter selection - - 0: Output frequency
1: Output current
2: Set frequency
3: DC voltage
4: Output voltage command value
5: Input power
6: Output power
7: Torque
8: Torque current
9: Motor cumulative load factor
10: Inverter cumulative load factor
11: - (do not select)
12: Frequency setting value (after
PID)
13: VIA Input value
14: VIB Input value
15: Fixed output 1 (Output current:
100%)
16: Fixed output 2 (Output current:
50%)
17: Fixed output 3 (Supposition
output at HOUN=17)
18: Serial communication data
19: For adjustments (HO set value is
displayed.)
05.4
HO
0006 Meter adjustment - - - -
V[R
0007 Default setting - - 0: -
1: 50Hz default setting
2: 60Hz default setting
3: Default setting (Initialization)
4: Trip record clear
5: Cumulative operation time clear
6: Initialization of type information
7: Save user setting parameters
8. Call user-defined parameters
9. Cumulative fan operation time
record clear
0 4.2.7
4.2.8
5.5
HT
0008 Forward/reverse
run selection
(Operation panel
operation)
- - 0: Forward run
1: Reverse run
2: Forward run (F/R switching
possible)
3: Reverse run (F/R switching
possible)
05.6
CEE
0009 Acceleration time
1
S 0.1/0.1 0.0-3200 *2 5.1.2
FGE
0010 Deceleration time
1
S 0.1/0.1 0.0-3200 *2
HJ
0011 Maximum
frequency
Hz 0.1/0.01 30.0-200.0 80.0 5.7
WN
0012 Upper limit
frequency
Hz 0.1/0.01 0.5-HJ 50.0 (WP)
60.0 (WN)
5.8
NN
0013 Lower limit
frequency
Hz 0.1/0.01 0.0-WN 0.0
XN
0014 Base frequency 1 Hz 0.1/0.01 25.0-200.0 50.0 (WP)
60.0 (WN)
5.9
XNX
0409 Base frequency
voltage 1
V 1/0.1 50-330 (200V class)
50-660 (400V class)
*1 5.9