5.2 Specifying an operation mode, using parameters
CW : Parameter setting macro function
Function
Automatically programs all parameters (parameters described below) related to the functions by selecting
the inverter's operating method.
The major functions can be programmed simply.
[Parameter setting]
Title Function Adjustment range Default setting
CW Parameter setting macro function
0: Disabled
1: Coast stop
2: 3-wire operation
3: External input UP/DOWN setting
4: 4-20mA current input operation
0:
Note:When this parameter is invoked after it has been set, is always displayed (on the right side).
The number on the left side refers to the number specified previously.
Example 
Automatically programmed functions and parameter set values
Relational
parameter
Default setting
value
1: Coast stop 2:3-wire
operation
3:External input
UP/DOWN
setting
4: 4-20mA
current input
operation
EOF 0: Terminal board 0: Terminal board 0: Terminal board 0: Terminal board 0: Terminal board
HOF 1: VIA 1: VIA 1: VIA
5:UP/DOWN
from external
contact
1: VIA
H (Always) 1: ST 0: Disabled 1: ST 1: ST 1: ST
H (F) 2:F 2:F 2:F 2:F 2:F
H (R) 3:R 1:ST 49:HD 41:UP 6:S1
H (RES) 10: RES 10: RES 10: RES 42:DOWN 10: RES
H 0 (%) - - - 20 (%)
See K-14 for input terminal functions.
Disabled (CW=)
The parameter does nothing. Even if set to , CW will not return the setting you made to its factory
default.