Toshiba VF-FS1 Power Supply User Manual


 
E6581381
C-3
3
3.1.1 How to start and stop
Example of a EOQF setting procedure
Key operated LED display Operation

Displays the operation frequency (operation stopped).
(When standard monitor display selection H= [Operation
frequency])
CWH
Displays the first basic parameter [Wizard function (CWH)].
EOQF
Press either the or key to select “EOQF”.
Press ENT key to display the parameter setting. (Default setting:).
Change the parameter to (panel) by pressing the key.
EOQF
Press the ENT key to save the changed parameter. EOQF and the
parameter set value are displayed alternately.
(1)Start and stop using the operation panel keys (EOQF=)
Use the and keys on the operation panel to start and stop the motor.
: Motor starts. : Motor stops.
+ To switch between forward run and reverse run from the control panel, the parameter HT
(forward/reverse run selection) needs to be set to or .
(2)RUN/STOP by means of an external signal to the terminal board (EOQF=):
Sink (Negative) logic
Use external signals to the inverter terminal board to start and stop the motor.
Short
and terminals: run forward
Frequency
ON
OFF
F-CC
Slow down
and stop
F
Open and terminals: slow down and stop
CC
F CC
(3)Coast stop
The standard default setting is for slowdown stop. To
make a coast stop, assign a "1(ST)" terminal function
to an idle terminal using the programmable terminal
function.
Change to
H
=
.
For coast stop, open the ST-CC when stopping the
motor in the state described at left.The monitor on the
inverter at this time will display
QHH
.
Motor
speed
ON
OFF
ON
OFF
F-CC
ST-CC
Coast stop
MODE
ENT
ENT
STOP
RUN
RUN
STOP