ADC Broadband System Network Router User Manual


 
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-97
© 2000, ADC Telecommunications, Inc.
DLP-530
Page 2 of 3
8110-C
ODS2 CONFIGURATION
Group: 3
Unit Equip State : EQUIPPED T2 Service State : IS
Unit Service State: IS BER Alarm Thresh: 1E-8
Unit Protect State: UNPROTECTED BER Switch Thresh: 1E-6
T1 Service Line
PARAMETERS Provision State Code Circuit ID
========= ======= ==== ====================
T1 #1: YES OOS AMI
T1 #2: YES OOS AMI
T1 #3: YES OOS AMI
T1 #4: YES OOS AMI
T1 Remote Pulse Remote Remote PPS
PARAMETERS Equalization Frame Format Threshold
=========== ============ =============
T1 #1: N/A N/A N/A
T1 #2: N/A N/A N/A
T1 #3: N/A N/A N/A
T1 #4: N/A N/A N/A
Remote Housekeeping Labels:
Working Card HSKP1: RMT-HSKP1 HSKP2: RMT-HSKP2
Protect Card HSKP1: N/A HSKP2: N/A
Press CONTROL-A For Assistance
Figure 530-1. ODS2 Configuration Screen
Table 530-1. ODS2 Configuration Fields
FIELD TYPE OPTIONS DESCRIPTION DEFAULT
Group Toggle 1, 2, 3, 4, 5, 6, or 7 Specifies the modules group number
designated on the chassis.
1
Unit Equipment
State
Toggle Equipped Establishes communication with MPU. Module
must be set to EQUIPPED before remaining
selections are allowed. Sets all other fields to
default values and allows MPU to process
equipment alarms.
UNEQUIPPED
UNEQUIPPED No communication with MPU.
Unit Service State Toggle IS (In-Service) Places the unit in service and allows equipment
alarm reporting by the MPU. Must be set to IS
for reporting of equipment alarms.
OOS
OOS (Out-Of-Service) Removes unit from service and stops equipment
alarm reporting by the MPU.
Unit Protect State Toggle PROTECTED Designates that equipment APS is available. UNPROTECTED
UNPROTECTED Designates that equipment APS is not available.
(continued)