ADC Broadband System Network Router User Manual


 
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-255
© 2000, ADC Telecommunications, Inc.
TAD-101
Page 7 of 9
Table 101-2. DS3 MUX Power Characteristics
MAX. POWER
CONSUMPTION/DISSIPATION
MAX. CURRENT DRAIN
(AT –48 VDC)
8 watts 166 mA
Note: Two DS3 MUXs (one working and one protect) are
used per chassis in Broadband (V5) applications.
Table 101-3. Broadband (V5) Power Characteristics with DLX
NO. OF DLXS IN
CHASSIS
MAX. POWER
CONSUMPTION/DISSIPATION
MAX. CURRENT DRAIN
(AT –48 VDC)
1 2 watts 41 mA
28 84 watts 1.8 amps
Note: Power characteristics for fully configured chassis include common
equipment: APU (7.5 watts), MPU (5 watts), and two DS3 MUX
modules (8 watts each), for a total of 28 watts.
Table 101-4. Broadband Power Characteristics with C1 HLXC
HLXR
CONFIGURATION
NO. OF C1 HLXCS
IN CHASSIS
MAX. POWER
CONSUMPTION
MAX. POWER
DISSIPATION
MAX. CURRENT DRAIN
(AT –48 VDC)
Span Powered B1
HLXR with DS1
Simplex Disabled
1
22.7 watts 11.9 watts 473 mA
28 664 watts 361 watts 13.8 amps
Span Powered B1
HLXR with DS1
Simplex Enabled
1
28.2 watts 12.4 watts 587 mA
28 818 watts 375 watts 17 amps
Local Powered B1
HLXR
1 8.9 watts 8.9 watts 248 mA
28
277 watts 277 watts 5.8 amps
Note: Power characteristics for fully configured chassis include common equipment: APU (7.5 watts), MPU
(5 watts), and two DS3 MUX modules (8 watts each), for a total of 28 watts.