ADC Broadband System Network Router User Manual


 
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-269
© 2000, ADC Telecommunications, Inc.
TAD-104
Page 4 of 11
Table 104-3. Expanded Scan Displays 2 Through 8 Definitions
DISPLAY MODULE TYPE DESCRIPTION
Lx
1
EQPT Fail QLX Module Fail, MPU COMM Fail, Laser Degrade, DS1 TX
LOS or (SISTER COMM Fail and not SISTER MPU
COMM Fail).
HLXC/RLX BOARD Fail or MPU COMM Fail
Lx
1
EQPT Fail RMT QLX Remote Board Fail
HLXC/RLX Not Applicable
Lx
1
Link ALM QLX DS2 OPTICAL COMM Fail, DS2 OPTICAL LOS, DS2
OPTICAL OOF, or DS2 OPTICAL BER
HLXC LOS, BER or SNR
RLX BER
Lx
1
RMT Link ALM QLX REMOTE OPTICAL COMM Fail, REMOTE DS2
OPTICAL LOS, REMOTE DS2 OPTICAL OOF, or
REMOTE OPTICAL DS2 BER
HLXC REMOTE LOSW, DC Loop Continuity (if HLXR is line
powered), BER, or SNR
RLX Not Applicable
Dx
1
SIG Fail QLX,/HLXC DS1 RX LOS
Dx
1
RMT SIG Fail QLX,/HLXC Remote DS1 RX LOS
Lx
1
RMT HSKP A/B QLX Remote Housekeeping Alarm A reported by QFLC. Remote
Housekeeping Alarm B is not applicable.
HLXC Remote Housekeeping Alarm A or B reported by an HLXR.
RLX Not Applicable
Lx
1
APS DIS QLX Lx
1
APS Status or Lx
1
APS lockout status
1
- x represents the chassis slot number.