ADC Broadband System Network Router User Manual


 
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-304
© 2000, ADC Telecommunications, Inc.
TAP-102
Page 5 of 11
Table 102-2. HDSL Mon Type Descriptions
MON TYPE MEANING LOCATION DESCRIPTION
FCP Failure Count Path NEND, FEND, REPC,
REPR, CRP, RRP*
Count of Loss Of Sync Word (LOSW)
failures on the HDSL loop.
CVP Code Violation Path NEND, FEND, REPC,
REPR, CRP, RRP
Count of CRC errors on the HDSL loop.
ESP Errored Second Path NEND, FEND, REPC,
REPR, CRP, RRP
A second in which one or more CRC
errors occurred on the HDSL loop, and
no LOSW defects occurred.
SESP Severely Errored
Second Path
NEND, FEND, REPC,
REPR, CRP, RRP
A second in which the number of CRC
errors on the HDSL loop was greater
than or equal to some user-specified
value, and no LOSW defects occurred.
SEFSP Severely Errored
Framing Second Path
NEND, FEND, REPC,
REPR, CRP, RRP
A second in which one or more LOSW
defects occurred on the HDSL loop.
PA-H Pulse Attenuation
High Path
NEND, FEND, REPC,
REPR, CRP, RRP
Highest Pulse Attenuation value detected
on the HDSL loop within the interval.
This value is only updated when the
HDSL loop is active. If the HDSL loop
has never been activated, this value will
be set to 0.
SNR-L Signal-to-Noise Ratio
Low Path
NEND, FEND, REPC,
REPR, CRP, RRP
Lowest SNR detected on the HDSL loop
within the interval. This value is only
updated when the HDSL loop is active.
If the HDSL loop has never been
activated, this value will be set to 71.
* For descriptions of locations where thresholds are monitored (such as FEND, NEND, REPC, REPR,
CRP, and RRP), refer to Figure 102-7 (T1 system), Figure 102-8 (HDSL system), Figure 102-9 (DLX