ADC Broadband System Network Router User Manual


 
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-110
© 2000, ADC Telecommunications, Inc.
DLP-533
Page 2 of 5
11783-A
RLX CONFIGURATION
Group: 1 Slot: 1 Circuit ID:
Unit Equip State : EQUIPPED Pulse Equalization : NOT APPL
Unit Service State: OOS LBO Setting : UNIT SWITCH
T1 Provision : YES Programmable Loopback : DISABLED
T1 Service State : OOS NID Loopback : ENABLED
Line Code : AMI Loopback Activation Code : 1101001111010011
Framing Format : AUTO Loopback Deactivate Code : 1001001110010011
Network DS1 Source: NRZ Lpbk Timeout Disable Code: 1101010111010110
BER Threshold : 1E-7 Loopback Timeout Period : 0 minutes
Span Power Setting: ENABLED Network Keep Alive : AIS
DS0 Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
(B = blocked) . . . . . . . . . . . . . . . . . . . . . . . .
Unit Switch Settings: Pulse Equalization: NOT APPL Span Power: DISABLED
NID: DISABLED LBO: 7.5 dB
Press CONTROL-A For Assistance
Figure 533-1. RLX Configuration Screen (Broadband Chassis)
Note:
The Unit Service State field default is UNEQUIPPED and the T1 Provision field
default is NO. When the Unit Service State field is set to EQUIPPED and the T1
Provision field is set to YES, this screen shows all other field defaults, as above.
Table 533-1. RLXIOR Configuration Fields
FIELD TYPE OPTIONS DESCRIPTION DEFAULT*
Group Toggle 1, 2, 3, 4, 5, 6, or 7
(groups 6 and 7 are not
available in the 19-inch
LEC chassis)
Specifies the modules group number
designated on the chassis.
1
Slot Toggle 1, 2, 3, or 4 Specifies the modules slot number in the
group designated on the chassis.
1
Circuit Identifier Input Enter up to 20 characters This represents the customers circuit ID.
The first and last characters must be alpha or
numeric; middle characters can be alpha,
numeric, or hyphens.
Blank
Unit Equip State Toggle Equipped Establishes communication with the MPU.
Module must be set to EQUIPPED before
remaining selections are allowed.
UNEQUIPPED
Unequipped No communication with the MPU.
*Note: The RLXIOR configuration field default values shown in this manual are valid for a system with an MPU installed.
(continued)