ADC Broadband System Network Router User Manual


 
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-122
© 2000, ADC Telecommunications, Inc.
DLP-536
Page 1 of 2
MENU SECURITY EDITING
Summary:
This procedure provides instructions to system administrators for assigning or
changing access user privilege levels to the Craft Interface menus.
Note:
A toggle field type means the user can press the space bar to view and select the
next option that is described; or the user can press the R key to view and select the
previous option. An input field type means the user must type an entry in the field
according to the parameters described. A fixed field is locked, and cannot be changed
by the user.
Note:
Edits can be
made
in the configuration database in one of two ways: 1) If the
complete field is highlighted, use the space bar to toggle forward or the R key to
reverse toggle through the options for that field. 2) If only the first space or the field is
highlighted, type in the data that applies to that field.
Note:
Edits to the configuration database can be
saved
after each change in one of two
ways: 1) Press an arrow key and then Enter or Return
once
; or 2) Press Enter or Return
twice
after all selections and entries are made in the screen but before leaving the screen.
Note:
Press CONTROL-A for help information on moving around and editing fields.
1. Use the arrow keys to select System Administration from the Main Menu. Press Enter or
Return.
2. Select Edit Menu Security from the System Administration menu. Press Enter or Return.
An Edit Menu Security screen (with default settings) appears as shown in Figure 536-1.
3. Use the arrow keys to move the cursor to the
Privilege
toggle field. Use the space bar to
select the privilege level (1 to 5). The lowest security level is 1; the highest level is 5.
Users assigned Level 5 have access to all menu selections; Level 5 is assigned to the
system administrator.
Level 3 is often assigned to the operating technician; users have access to Levels 1, 2,
and 3.
Level 2 is normally assigned to a local technician; users have access to Levels 1 and 2.
Users assigned Level 1 have access to only those menus assigned a Level 1.
4. Repeat Step 3 for each Main Menu Selection that you wish to change.
Note:
Disregard the QLX Alarm Levels and QLX Configuration selections. The MPU
software installed is used with either the Soneplex Broadband system or the Soneplex
Loop Extender. QLX modules are not used in the Broadband chassis.
5. Assign the selections by pressing Enter or Return.
Stop! You have completed this procedure.