ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-14
© 2000, ADC Telecommunications, Inc.
NTP-004
Page 1 of 2
SYSTEM OR CIRCUIT PROVISIONING PROCEDURES
Summary
: This procedure tells how to provision (turn-up) a new Soneplex system or circuit
using the Craft Interface. The procedure assumes the equipment in the Soneplex chassis and the
equipment at the other end of the circuit has been installed, and has passed all local and end-to-
end tests. Some procedures may not be required and will depend upon how the system is
equipped. This procedure must be performed before attempting to operate the entire circuit or
system that will be using this equipment.
Do Items Below For Details Go To
1. Log on to the Craft Interface. DLP-526
2. Clear Alarm History (required only for a new installation). DLP-527
3. Set system date and time, and enter the Target Identifier. DLP-528
4. Set Craft Interface port configuration:
• For Craft Port on MPU or Port 2 DLP-549
• For X.25 Port DLP-558
5. Edit Menu Security (set privilege levels). DLP-536
6. Edit User Accounts (set user IDs and passwords). DLP-535
7. Assign names to Housekeeping Alarm contacts. DLP-550
8. Configure the DS3 MUX as required, set service state, and set
protect status. If required, insert Line Build-Out on the transmit
side of the DS3 signal. DLP-529
9. If present, equip ODS2 modules; assign service state and line code
for each DS1 on the ODS2 module. DLP-530
10. If present, equip Version C, D, E, or G HLXC modules and
provision HDSL circuits. DLP-516
11. If present, equip DLX modules and provision DS1 circuits. DLP-532
12a. If present, equip RLX modules and provision DS1 circuits. DLP-534
AND/OR
12b. If present, equip RLXIOR modules and provision DS1 circuits. DLP-533
13. Assign performance monitoring thresholds for each DS1 in the
system. DLP-556