TAU INSTALLATION AND TESTING
Summary:
This procedure provides instructions for installing the Test Access Unit (TAU) in the
chassis and verifying that it is functioning properly. The TAU requires no provisioning or
periodic maintenance.
Caution:
Modules can be damaged by electrostatic discharge (ESD). Before handling
any modules, ESD protection must always be used. An ESD grounding post is located on
the chassis for connecting the ESD wrist band. Ensure that all modules removed from
the equipment or not installed, are properly stored in anti-static packing material. When
working with modules, always place the module on an electrically-grounded, approved,
anti-static mat.
Note:
For information about installing and testing the TAU, which is used with MPU
Software Version 5.3, refer to the Soneplex Test Access Unit Installation Instructions
manual, listed under Related Publications at the beginning of this manual.
1. Remove the TAU from its protective packaging.
2. Insert the TAU into the full height chassis slot labeled TAU (as shown in Figure 574-1)
until it reaches the backplane connector.
3. Using the ejectors, fully seat the TAU in the chassis. A moderate amount of force may be
required to properly seat the module in the backplane connector.
4. Did the STATUS indicator light green?
If Yes, you have completed this procedure.
If No, replace the TAU and return to Step 1.
Stop! You have completed this procedure.
5841-A
TAU MODULE
HSW
HSP
TAU
APU
MPU
MXPMXW
DS3 FAIL
RESET
LMPTST/
APS
LPBK
ENABLE
ONLINE
STATUS
APS LOCKOUT
FORCE
DS3 FAIL
RESET
LMPTST/
APS
LPBK
ENABLE
ONLINE
STATUS
APS LOCKOUT
FORCE
CR
MJ
MN
APU
ACO
PWR
HSKP
RMT
ALM
LMPTST
DISP RMT
STATUS
RESET
1-31-1 2-1 2-3 3-1 3-3 4-1 4-3 5-1 5-3 6-1 6-3 7-1 7-3
1-41-2 2-2 2-4 3-2 3-4 4-2 4-4 5-2 5-4 6-2 6-4 7-2 7-4
DS3 FAIL
DS3 FAIL
DS3 FAIL
DS3 FAIL
TAU
Figure 574-1. TAU Mounting Position in the Soneplex Broadband Chassis