ADC Broadband System Network Router User Manual


 
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-181
© 2000, ADC Telecommunications, Inc.
DLP-556
Page 2 of 3
6. Move to the
Mon Type Alarms
toggle fields. The following selections are possible:
Critical Allows notification of all Critical, Major, Minor, and Event alarms as they
occur.
Major Allows notification of all Major, Minor, and Event alarms as they occur.
Minor Allows notification of all Minor and Event alarms as they occur.
Event Allows notification of all events as they occur.
Reference
: TAP-101 Alarm Troubleshooting
7. Assign the selections by pressing Enter or Return.
8. Repeat Steps 3 through 7 for each applicable DS1 signal in the chassis.
Note:
Pressing CONTROL-C and confirming with the Y key removes all threshold
values and alarm level information from the database for the group and slot selected.
Stop! You have completed this procedure.
6146-B
DS1 PERFORMANCE MONITORING CONFIGURATION
Group: 1 Circuit: 1 Circuit ID:
15 MINUTE DAILY 15 MINUTE DAILY
MON ============== ================ MON ============== ================
TYPE THRSH ALM LVL THRSH ALM LVL TYPE THRSH ALM LVL THRSH ALM LVL
==== ===== ======== ======= ======== ======== ===== ======== ======= ========
FCP 5 EVENT 480 EVENT AISSP 10 EVENT 100 EVENT
CVL 13340 EVENT 133400 EVENT FCP-FE 5 EVENT 480 EVENT
ESL 65 EVENT 648 EVENT ESL-FE 65 EVENT 648 EVENT
SESL 10 EVENT 100 EVENT CVP-FE 13340 EVENT 133400 EVENT
LOSS 10 EVENT 100 EVENT ESP-FE 65 EVENT 648 EVENT
CVP 13340 EVENT 133400 EVENT SESP-FE 10 EVENT 100 EVENT
ESP 65 EVENT 648 EVENT UASP-FE 10 EVENT 100 EVENT
SESP 10 EVENT 100 EVENT CSSP-FE 10 EVENT 100 EVENT
UASP 10 EVENT 100 EVENT SEFSP-FE 10 EVENT 100 EVENT
SASP 10 EVENT 100 EVENT
CVs PER SESL: 1544 CVs PER SESP: 330 CVs PER SESP-FE: 330
Press CONTROL-A For Assistance, CONTROL-C To Clear All PM Counts
* Indicates valid range of values for selected field. See Table 556-1.
Figure 556-1. DS1 PM Configuration Screen