Table 533-1. RLXIOR Configuration Fields, continued
FIELD TYPE OPTIONS DESCRIPTION DEFAULT*
Span Power
Setting**
Toggle UNIT SWITCH Stops span power on the RLXIOR. ENABLED
ENABLED Enables span power using the on-board
switch settings (130V or ±130V). The
default switch setting is 130V.
DISABLED Stops span power on the RLXIOR.
Pulse
Equalization**
Toggle UNIT SWITCH Selecting this option on the RLXIOR
creates a setting of 0133 ft.
UNIT SWITCH (Loop
Extender chassis only)
0133 ft., 133266 ft.,
266399 ft., 399533 ft.,
or 533655 ft.
The DS1 signal output provides standard
DSX signal levels which can be
compensated for various distances.
NOT APPL (locked field
in Broadband chassis
only)
LBO Setting** Toggle UNIT SWITCH Selecting this option on the RLXIOR
creates a setting of 0.0 dB.
UNIT SWITCH
0.0 dB, 7.5 dB, 15.0 dB,
or 22.5 dB
Sets the LBO in decibels.
Programmable
Loopback
Toggle ENABLED Enables response to programmable
loopback codes.
DISABLED
DISABLED Disables response to programmable
loopback codes.
NID Loopback** Toggle UNIT SWITCH Disables loop-up response to NID arming
code. The loopback armed state transitions
to "Armed" when the NID arming code is
received.
ENABLED
ENABLED Enables response to NID loopback codes.
DISABLED Disables loop-up response to NID arming
code. The loopback armed state transitions
to "Armed" when the NID arming code is
received.
*Note: The RLXIOR configuration field default values shown in this manual are valid for systems with an MPU installed.
**Note: Although unit switch settings (Pulse Equalization, Span Power, NID Loopback, and LBO) are shown at the bottom of the
configuration screen, none of the displays are meaningful for the RLXIOR. First, there are no on-board switches for Pulse
Equalization, NID Loopback, and LBO. In addition, although the RLXIOR has an on-board Line Power switch, the Span Power
unit switch setting display is locked at DISABLED.