ADC Broadband System Network Router User Manual


 
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-194
© 2000, ADC Telecommunications, Inc.
DLP-561
Page 2 of 3
7. Move to the
DS1 Facility Alarms
toggle fields. Select
CRITICAL, MAJOR, MINOR,
EVENT, or NOT RPTD for each field that you wish to change.
Reference
: TAP-101 Alarm Troubleshooting
Note:
Default values are listed in Table 561-1.
8. Assign the selections by pressing Enter or Return.
Stop! You have completed this procedure.
.
6152-C
ODS2 ALARM LEVELS
Group: 3
Equipment Alarms
==============================================================
BOARD FAIL : MAJOR PROTECT COMM FAIL: MINOR
COMM FAIL : MAJOR REMOTE COMM FAIL : MINOR
CONFIG MISMATCH: MINOR VERSION MISMATCH : MINOR
HSKP1 : MINOR HSKP2 : MINOR
DS2 Facility Alarms
==============================================================
APS LIMIT : MINOR OPTICAL LOF : MAJOR
FORCE TO WORK : MINOR OPTICAL LOS : MAJOR
FORCE TO PROT : MINOR T-BER : MINOR
LASER DEGRADE : MINOR
DS1 Facility Alarms DS1 #1 DS1 #2 DS1 #3 DS1 #4
======================== ========= ========= ========= =======
LOOPED BACK : MINOR MINOR MINOR MINOR
RECEIVE LOS : MAJOR MAJOR MAJOR MAJOR
TRANSMIT EXZ : MINOR MINOR MINOR MINOR
RECEIVE AIS : EVENT EVENT EVENT EVENT
Press CONTROL-A For Assistance
Figure 561-1. ODS2 Alarm Levels Screen