ADC Broadband System Network Router User Manual


 
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-274
© 2000, ADC Telecommunications, Inc.
TAD-104
Page 9 of 11
Table 104-4. Compressed TBOS Scan Display Definitions
DISPLAY UNIT TYPE DESCRIPTION
Critical Alarm Shelf Critical Alarm shelf summary
Major Alarm Shelf Major Alarm shelf summary
Minor Alarm Shelf Minor Alarm shelf summary
Remote Alarm Shelf Remote Alarm shelf summary
Power Alarm Shelf Shelf Power A or B input failure (but not both)
HSW Eqpt Alm N/A Not Applicable for this release
HSP Eqpt Alm N/A N/A for this release
HWS Fac Alm N/A N/A for this release
HSP Fac Alm N/A N/A for this release
MXW Eqpt Alm
MXP Eqpt Alm
DS3 MUX Unit Fail, MPU COMM Fail, DS3 TX LOS, or (SISTER COMM Fail and not SISTER
MPU COMM Fail)
MXW Fac Alm
MXP Fac Alm
DS3 MUX DS3 RX LOS, DS3 RX OOF, DS3 Loopback
Dx
a
L/R Alarm ODS2 & QLX DS2 Optical COMM Fail, DS2 Optical LOS, DS2 Optical OOF, DS2 Optical BER,
DS1 RX LOS, DS1 Loopback
Dx L/R Alarm HLX DS1 RX LOS, HDSL LOSW, HDSL BER, HDSL SNR, DC Loop Continuity (if HLXR
is line powered), DS1 Loopback
Dx L/R Alarm RLX DS1 RX LOS, DS1 RX LOF, DS1 Loopback
Dx L/R Alarm DLX DS1 RX LOS, DS1 BER, DS1 Loopback
HSKPx Rmt Alm ODS2 & QLX Slot number is x-1: HSKP1 alarm reporting by QFLC or QLX working.
Slot number is x-2: HSKP2 alarm reporting by QLX working only.
Slot number is x-3: HSKP3 alarm reporting by QFLC or QLX working.
Slot number is x-4: HSKP4 alarm reporting by QLX working only.
HSKPx Rmt Alm HLX Remote Housekeeping Alarm A or B reported by an HLXR
HSKPx Rmt Alm RLX N/A
HSKPx Rmt Alm DLX N/A
Lx Lcl Alarm ODS2 & QLX Unit Fail, MPU COMM Fail, Laser Degrade, DS1 TX LOS, or (SISTER COMM Fail
and not SISTER MPU COMM Fail)
Lx Lcl Alarm HLX Unit Fail, MPU COMM Fail
Lx Lcl Alarm RLX Unit Fail, MPU COMM Fail
Lx Lcl Alarm DLX MPU COMM Fail
Lx Rmt Alarm ODS2 & QLX Remote Unit Fail
Lx Rmt Alarm HLX N/A
Lx Rmt Alarm RLX N/A
Lx Rmt Alarm DLX N/A
a
“x” represents the Soneplex chassis (shelf) slot number