PERFORMANCE MONITORING REPORTING LOCATIONS
Summary:
Performance Monitoring (PM) information for both DS1 and HDSL is found on the
MPU’s main menu under Performance Monitoring. The following information is designed to
show where the PM information is being reported from (that is, Near End [NEND] and Far End
[FEND] PM report locations). Refer to Figure 103-1 for a drawing of the Soneplex HDSL
system. Refer to Figure 103-2 for a drawing of the Soneplex T1 Repeater (RLX) system. Refer to
Figure 103-3 for a drawing of the Soneplex Optical DS2 (QLX) system.
Soneplex HDSL System
A
H
NEND NEND
CSUCSU
HLXC HLXR
HRX
C
B
DEF
G
14861-A
NETWORK
LOOP 1 LOOP 1
LOOP 2 LOOP 2
DS1 DS1HDSLHDSL
FEND
FEND
Figure 103-1. Location of Critical Alarm Points on Soneplex HDSL System
A
= External CSU that will inject PRM (Performance Report Messages) back to
B
reporting all DS1 Far End Alarms. Errors or problems received at
A
are
reported back to
B
via the PRM in the FDL (Facility Data Link).
B
= DS1 errors at HLXC are reported as
T1-1-X-X-1 NEND
PM and alarms.
Report measures the actual DS1 performance as received from CSU
A
.
- OR -
DS1 errors at HLXC are reported as
T1-1-X-X-1 FEND
PM and alarms from
CSU
A
via the PRM in the FDL (Facility Data Link).
C
= HDSL errors at HLXC are reported as
HDSL-1-X-X-1
(Loop 1) or
HDSL-1-
X-X-2
(Loop 2)
NEND
PM and alarms.
D
= HDSL errors at HRX
are reported as
HDSL-1-X-X-1
(Loop 1) or
HDSL-1-X-
X-2
(Loop 2)
REPR
PM and alarms at
HRX
on CO side.
E
= HDSL errors at HRX are reported as
HDSL-1-X-X-1
(Loop 1) or
HDSL-1-X-
X-2
(Loop 2)
NEND
PM and alarms at
HRX (REPC)
on CPE side.
F
= HDSL errors at HLXR are reported as
HDSL-1-X-X-1
(Loop 1) or
HDSL-1-
X-X-2
(Loop 2)
FEND
PM and alarms.