ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-115
© 2000, ADC Telecommunications, Inc.
DLP-534
Page 2 of 6
6127-C
RLX CONFIGURATION
Group: 1 Slot: 1 Circuit ID:
Unit Equip State : EQUIPPED Pulse Equalization : NOT APPL
Unit Service State: OOS LBO Setting : UNIT SWITCH
T1 Provision : YES Programmable Loopback : DISABLED
T1 Service State : OOS NID Loopback : UNIT SWITCH
Line Code : AUTO Loopback Activation Code : 1101001111010011
Framing Format : AUTO Loopback Deactivate Code : 1001001110010011
Network DS1 Source: NRZ Lpbk Timeout Disable Code: 1101010111010110
BER Threshold : 1E-7 Loopback Timeout Period : 0 minutes
Span Power Setting: UNIT SWITCH Network Keep Alive : AIS
DS0 Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
(B = blocked) . . . . . . . . . . . . . . . . . . . . . . . .
Unit Switch Settings: Pulse Equalization: NOT APPL Span Power: DISABLED
NID: DISABLED LBO: 7.5 dB
Press CONTROL-A For Assistance
Figure 534-1. RLX Configuration Screen
Table 534-1. RLX Configuration Fields
FIELD TYPE OPTIONS DESCRIPTION DEFAULT
Group Toggle 1, 2, 3, 4, 5, 6, or 7
(groups 6 and 7 are not
available in the 19-
inch chassis)
Specifies the module’s group number
designated on the chassis.
1
Slot Toggle 1, 2, 3, or 4 Specifies the module’s slot number
designated on the chassis.
1
Circuit Identifier Input Enter up to 20
characters
This represents the customer’s circuit ID.
The first and last characters must be alpha
or numeric; middle characters can be alpha,
numeric, or hyphens.
Blank
Unit Equip State Toggle Equipped Establishes communication with MPU.
Module must be set to EQUIPPED before
remaining selections are allowed.
UNEQUIPPED
Unequipped No communication with MPU.
(continued)