ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-184
© 2000, ADC Telecommunications, Inc.
DLP-557
Page 2 of 3
6. Move to the
Mon Type Alarms
toggle fields. The following selections are possible:
• Critical
–
Allows notification of all Critical alarms as they occur.
• Major
–
Allows notification of all Major and Critical alarms as they occur.
• Minor
–
Allows notification of all Minor, Major, and Critical alarms as they occur.
• Event
–
Allows notification of all alarms and events as they occur.
Reference:
TAP-101 Alarm Troubleshooting
7. Assign the selections by pressing Enter or Return.
8. Repeat Steps 3 through 7 for each HDSL facility in the chassis.
Note:
Pressing CONTROL-C and confirming with Y removes all threshold values and
alarm level information from the database for the group and slot selected.
Stop! You have completed this procedure.
6147-B
HDSL PERFORMANCE MONITORING CONFIGURATION
Group: 6 Circuit: 1 Circuit ID:
15 MINUTE DAILY
=================== ===================
MONTYPE THRESHOLD ALM LEVEL THRESHOLD ALM LEVEL
======= ========= ========= ========= =========
FCP 5 EVENT 480 EVENT
CVP 6893 EVENT 67579 EVENT
ESP 65 EVENT 648 EVENT
SESP 10 EVENT 100 EVENT
SEFSP 10 EVENT 100 EVENT
CVs PER SES: 165
Press CONTROL-A For Assistance, CONTROL-C To Clear All PM Counts
Figure 557-1. HDSL PM Configuration Screen (Typical)