Honeywell VM2 Laptop User Manual


 
4 - 46
Wiring Diagram
CAUTION
For battery powered vehicles:
must be connected to the vehicle chassis ground.
For internal combustion engine powered vehicles:
is connected to the vehicle chassis ground, which can also be battery negative.
WARNING
For proper and safe installation, the input power cable must be connected to a fused circuit on the vehicle.
If the supply connection is made directly to the battery, the fuse should be installed in the positive lead within
5 inches of the battery’s positive (+) terminal. The fused circuit requires a maximum time delay (slow blow)
fuse with a current rating as noted below.
•For 60VDC input, use a 6A slow blow fuse that has a DC voltage rating greater than 60VDC.
•For 72VDC input, use a 6A slow blow fuse that has a DC voltage rating greater than 72VDC.
•For 96VDC input, use a 4A slow blow fuse that has a DC voltage rating greater than 96VDC.
•For 108VDC input, use a 4A slow blow fuse that has a DC voltage rating greater than 108VDC.
•For 120VDC input, use a 4A slow blow fuse that has a DC voltage rating greater than 120VDC.
•For 132VDC input, use a 3A slow blow fuse that has a DC voltage rating greater than 132VDC.
•For 144VDC input, use a 3A slow blow fuse that has a DC voltage rating greater than 144VDC.
Note: For North America, a UL Listed fuse is to be used.
Power
Connector
-
-
-Vo
Black
Green
Blue
(not connected)
+Vo
COM1 or COM2
Connector
+
+
User supplied serial
cable for optional
screen blanking
connection,
see below
Existing Circuitry on Vehicle
Forklift Battery
Main Switch
Quick Mount
Smart Dock
DC/DC
Power
Supply
Fuse - See
Warning
statement below
See
Caution
statement below
Red
Red/White (if present)
Black/White (if present)
!
!