The Object Dictionary
146
1606218 02 08/2006
Object 1010H: Store Parameters
Description This object is used to store the parameters of the splitter box in backed up memory.
Characteristics The characteristics of this object are outlined in the following table:
Operation To save the parameters, the "save" ASCII character string (6576 6173H) must be
written to the corresponding sub-index:
The read result of a sub-index is always 0000 0001H.
Sub-index Description Data type Default
value
Acces
s
PDO
Mapping
Backed up
0 Sub-index number UNSIGNED8 4 ro no no
1 Store all parameters UNSIGNED32 - rw no no
2 Store communication
parameters (1000H–
1FFFH)
UNSIGNED32 - rw no no
3 Store standardized
application parameters
(6000H–9FFFH)
UNSIGNED32 - rw no no
4 Store manufacturer-
specific application
parameters (2000H–
5FFFH)
UNSIGNED32 - rw no no
Most significant word Least significant
word
Hex value 65H 76H 61H 73H
ISO 8859 (ASCII)
signature
evas