Schneider Electric IP67 Computer Hardware User Manual


 
Application-Specific Functions
76
1606218 02 08/2006
Description of Configurable Discrete I/Os
Configurable
Splitters
The configurable splitter boxes are as follows:
FTB 1CN16CP0
FTB 1CN16CM0
FTB 1CN08E08CM0
Channel
Configured for
Discrete Output
Write outputs are per word. Each output word is contained in the sub-index of object
6200H.
For each output, the following parameters may be modified:
Polarity (object 6302H)
Filter mask (object 6308H)
In the event of an error (loss of communication with the master for example), the
fallback mode is applied.
The state applied to the output is determined by the configuration registers as
described below:
OPTIO-
NAL
FILTER
6306H
SWITCH
IF 0H
Single
Digital
Output
Change
Polarity
{OH,1H}
{O,1}
CHANGE
POLAR-
ITY
ENTRY
into 6200H
6300H
6307H
Fallback Value
Filter
Mask
{E,D}
{O,1}
Switch if
Device
Failure
Fallback Mode
{O,1}
{O,1}
{E,D}
{O,1}
6302H 6308H