Schneider Electric IP67 Computer Hardware User Manual


 
The Object Dictionary
148
1606218 02 08/2006
Object 1011H: Restore Default Parameters
Description This object is used to restore the FTB splitter box's "factory" settings.
Characteristics The characteristics of this object are outlined in the following table:
Operation To restore the parameters, the "load" ASCII character string (64616F6CH) must be
written to the corresponding sub-index:
The read result of a sub-index is always 0000 0001H.
Sub-index Description Data type Default
value
Acce
ss
PDO Mapping Backed up
0 Sub-index number UNSIGNED8 4 ro no no
1 Restore all default
parameters.
UNSIGNED32 - rw no no
2 Restore default
communication
parameters (1000H–
1FFFH).
UNSIGNED32 - rw no no
3 Restore default
standardized application
parameters (6000H–
9FFFH).
UNSIGNED32 - rw no no
4 Restore default
manufacturer-specific
application parameters
(2000H–5FFFH).
UNSIGNED32 - rw no no
Most significant word Least significant
word
ISO 8859
(ASCII)
signature
daol
Hex value 64H 61H 6FH 6CH