Schneider Electric IP67 Computer Hardware User Manual


 
Installation
1606218 02 08/2006 17
Installing the Unit
Introduction This section gives a detailed technical description of Advantys FTB splitter boxes.
Description The Advantys FTB splitter box can be mounted directly onto a wall or a machine.
Two mounting holes have been provided for this purpose inside the splitter box.
Types of Screws
and Tightening
Torques
Plastic unit
The plastic splitter box is mounted using two 4 mm (0.16 in.) diameter screws and
two washers. The tightening torque is 1.5 Nm (13.3 lb-in).
Metal unit
The metal splitter box is mounted using two 6 mm (0.24 in.) diameter screws and
two washers. The tightening torque is 9 Nm (79.7 lb-in).
Note: When mounting the unit, the support must be flat and smooth so as to
prevent any undue stress on the unit, which may lead to a loss of sealing.
Note: For metal units, wire the ground terminal before attaching the splitter box to
its support. See Grounding of the Advantys FTB Splitter Box, p. 21.