Application-Specific Functions
92
1606218 02 08/2006
List of FTB
1CN08E08CM0
Input Objects
The list of input objects for the Advantys FTB 1CN08E08CM0 splitter box is given in
the following table:
Object Sub-
index
Bit Description
2000H 1 Bit 0 Choice between the "input" function and the "diagnostics input"
function for channel 10
... ...
Bit 7 Choice between the "input" function and the "diagnostics input"
function for channel 17
6000H 1 Bit 0
Channel 0 input reading if channel 0 configured for input
Not assigned if channel 0 configured for output
... ...
Bit 7
Channel 7 input reading if channel 7 configured for input
Not assigned if channel 7 configured for output
2Bit 0
Channel 10 input reading if channel 10 configured for input
Channel 10 diagnostics input reading if channel 10 configured
for diagnostics input
... ...
Bit 7
Channel 17 input reading if channel 17 configured for input
Channel 17 diagnostics input reading if channel 17 configured
for diagnostics input
6100H 1 Bit 0
Channel 0 input reading if channel 0 configured for input
Not assigned if channel 0 configured for output
... ...
Bit 7
Channel 7 input reading if channel 7 configured for input
Not assigned if channel 7 configured for output
Bit 8
Channel 10 input reading if channel 10 configured for input
Channel 10 diagnostics input reading if channel 10 configured
for diagnostics input
... ...
Bit 15
Channel 17 input reading if channel 17 configured for input
Channel 17 diagnostics input reading if channel 17 configured
for diagnostics input