Schneider Electric IP67 Computer Hardware User Manual


 
The Object Dictionary
1606218 02 08/2006 165
Transmission
mode
The PDO transmission mode can be configured as described in the table below.
COB-ID
Structure
The structure of a COB-ID for CAN2.0 is shown in the following table:
Transfer code Transmission mode Notes
Dec. Hex. Cyclic Acyclic Synchrono
us
Asynchron
ous
RTR only
0 0 x x Send PDO on first
SYNC message
following an event
1 to 240 1 to F0 x x Send PDO every x
SYNC messages
241 to 251 F1 to FB Reserved -
252 FC x x Receive SYNC
message and send
PDO on Remote
Request
253 FD x x Update data and send
PDO on Remote
Request
254 to 255 FE to FF x Send PDO on event
(Change of state
mode)
Note: For transmission modes corresponding to transfer codes 254 and 255, the
events that trigger a TPDOtransmission are:
modification of transported data status,
the Event Timer has elapsed.
Bit No. Value Meaning
31 (MSb) 0 The PDO object exists
1 The PDO object does not exist
30 0 RTR mechanism authorized
1 RTR mechanism not authorized
29 0 11-Bit ID (CAN 2.0A)
28 - 11 0 if bit 29 = 0
10 - 0 (LSb) X Bit 10 - 0 of the identifier