Fujitsu M10-4S Server User Manual


 
Caution -
Before you handle any components, wear a wrist strap to ground any static
electricity. If you perform this procedure without a wrist strap, individual
components or the overall system may be damaged. For details, see "1.5 Notes
Regarding Static Electricity."
Note -
Record the positions of the cables before removing them to ensure that they are
reinstalled correctly.
A
M10-4S with a FRAME-A CPU memory unit.
7.4.1 Accessing a CPU memory unit
1.
Remove the crossbar cables f rom the cable support.
Perform this procedure only when using equipment rack model 26xx or
equipment rack model 16xx. The procedure may vary depending on the model
of the equipment rack.
If you are not using equipment rack model 26xx or equipment rack model 16xx,
proceed on to step 2.
Procedure when equipment rack model 2 6 xx is used
a.
Remove all the crossb ar cables from the crossb ar unit.
b.
Remove the hook-and-loop fastener of the cable supp ort (A in the figure) t o
which the crossbar cables a re fixed.
Figure 7-3
Hook-and-loop fastener of the cable support
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 201392