Fujitsu M10-4S Server User Manual


 
Table 4-8
Types of maintenance for cables and dedicated power distribution unit (continued)
Supported: Maintenance can be performed / Unsupported: Maintenance cannot be performed
FRU Active/hot Active/cold Inactive/hot Ina c tive/cold System stopped Refer e nc e
XSCF BB control
cable
Supported
(*1)
Supported Supported Supported Supported Chapter
26
XSCF DUAL control
cable
Supported
(*1)
Supported Supported Supported Supported Chapter
27
Cable kit Unsupported Unsupported
(*2)
Unsupported Unsupported
(*2)
Supported
(*3)
Chapter
28
Dedicated power
distribution unit
Unsupported Supported Unsupported Unsupported Supported Chapter
29
*1: The XSCF must be configured as a slave before maintenance is started. If the XSCF is operating as the master XSCF, switch it to a
standby XSCF.
*2: If any physical partition is currently operating, the crossbar box cannot be powered off.
*3: All the physical partitions must be powered off, and the system must be completely shut down.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 201352