Fujitsu M10-4S Server User Manual


 
Table 13-2
Maintenance flow
Details of update process Replacement Expansion Reduction
1Pre-check 13.3 13.3 13.3
2 Preparation 13.4 13.4 13.4
3 Removing a PCIe card or the filler for a
PCIe card
13.5 13.5 13.5
4 Installing a PCIe card or the filler for a
PCIe card
13.6 13.6 13.6
5 Restoring the system 13.7 13.7 13.7
13.2.3 Precautions for replacement
Note the following points when replacing PCIe cards.
For active maintenance by PHP, a multipath setting is necessary depending on the
use of the PCIe cards.
13.2.4 Precautions for installation
Note the following points when performing PCIe card expansion.
Set a multipath depending on the use of the PCIe card when performing active/hot
maintenance or active/cold maintenance with PHP.
If you are performing PCIe card expansion, remove the filler for the PCIe card
from the PCIe card cassette.
Keep the removed filler because it will be needed if PCIe card reduction is
subsequently done.
13.2.5 Precautions for removal
Note the following points when removing PCIe cards.
Set a multipath depending on the use of the PCIe card when performing active/hot
maintenance or active/cold maintenance with PHP.
If you are removing a PCIe card, attach the filler for the PCIe card after removing
the PCIe card from the PCIe card cassette.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013242