Fujitsu M10-4S Server User Manual


 
XSCF>
testsb -y -p 00-0
Note -
Inactive/cold maintenance can be performed only for a building block configuration.
The inactive/cold maintenance procedure for a single-chassis configuration is the same as
that for stopping the system.
2.
Return t o the op eration of the XSCF firm w are replacefru command to confirm
that th e chassis has been incorporat ed into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3.
Execute the testsb command to confirm that th e internal dis k requiring
maintenance is normally recognized.
When you enter the "-y" option for the testsb command, the system automatically
answers "y" (yes) in response to an inquiry.
The following example shows the diagnosis of system board 00-0.
During the diagnosis processing, the probe-scsi-all command of the OpenBoot
PROM is executed, and the result is displayed.
4.
Incorporate t he chassis, in which the internal disk requiring maintenance is
mounted, into the physical partition.
For details, see "6.2 Incorporating a Chassis into a Physical Partition."
5.
Close t he rack d oor.
12.6.3 Inactive/Hot maintenance
For a single-chassis configuration
1.
Start th e entire system.
For details, see "6.4 Starting the Entire System."
2.
Close t he rack d oor.
For a building-block configuration
1.
Pow er on the physical p artition requiring main t enan ce.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
2.
Close t he rack d oor.
12.6.4 Inactive/Cold maintenance
1.
Connect all the pow er c ords to t he PSU backplane unit o f the chassis
requiring mai nten ance.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013236