Fujitsu M10-4S Server User Manual


 
XSCF>
showstatus
XSCF>
showhardconf
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
19.6.1 Active/Hot maintenance
1.
Return t o the op eration of the XSCF firm w are replacefru command to confirm
that th e fan un it has be en incorporated into the sy stem.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
2.
Execute the sho w status command to confirm that there is no problem with
the f an unit after the co mpletion of maintenan ce.
3.
Execute the sho w h ardconf command t o check the hardware configuration
and t he status of each component.
4.
Close t he rack d oor.
19.6.2 Inactive/Hot maintenance
1.
Return t o the op eration of the XSCF firm w are replacefru command to confirm
that th e fan un it has be en incorporated into the sy stem.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
2.
Pow er on the physical p artition requiring main t enan ce.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
3.
Close t he rack d oor.
19.6.3 System-stopped maintenance
1.
Connect all the po wer c ords to the po wer s upply unit of the crossbar box
requiring mai nten ance.
For details, see "6.5.1 Installing the power cord."
2.
Return t o the op eration of the XSCF firm w are replacefru command to confirm
that th e fan un it has be en incorporated into the sy stem.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013334